Product Advantages

 

 

Extra-wide doors for easy hospital bed access. Smooth acceleration and deceleration to reduce motion sickness. Optional antibacterial handrails, UV disinfection system, and emergency communication devices.

 

 
  • Hospital Stretcher Elevator
    FUJIEPS Hospital Stretcher Elevator is a dedicated hospital elevator designed specifically for medical facilities. Its spacious car interior is engineered to accommodate stretchers, hospital beds,
  • Hospital Bed Elevator
    Featuring a spacious car interior, it delivers smooth, quiet operation with simple and precise control. Designed to accommodate hospital beds and medical equipment with minimal noise, it incorporates
  • Hospital Pattern Elevator
    FUJIEPS Hospital Pattern Elevators are a general category of professional elevators, including bed elevators and freight elevators, among other types. Custom-engineered to meet the unique operational
 
Technical Specifications

Hospital elevators are engineered according to building layouts, patient transportation requirements, and applicable regional elevator regulations. The specification ranges below provide an engineering baseline for preliminary project evaluation.

Parameter

Metric Specification

Imperial Specification (US/Global)

Rated Load Capacity

1000 kg – 2500 kg

2200 lbs – 5500 lbs

Rated Speed

0.5 m/s – 2.5 m/s

100 fpm – 500 fpm

Car Internal Dimensions (W x D)

Custom sizing; standard medical bed configurations available

Custom sizing; standard medical bed configurations available

Clear Door Opening (W x H)

Typically 1100 x 2100 mm to 1400 x 2100 mm

Typically 43" x 83" to 55" x 83"

Maximum Travel Height

Up to 80 meters

Up to 260 feet

Maximum Stops / Floors

Up to 26 stops

Up to 26 stops

Drive Type

VVVF gearless traction / optional hydraulic configuration

VVVF gearless traction / optional hydraulic configuration

Leveling Accuracy

Typically plus or minus 3 mm (system dependent)

Typically plus or minus 1/8" (system dependent)

Power Supply

380V/415V, 3-phase, 50Hz/60Hz

208V/480V, 3-phase, 60Hz (Customizable)

 

Working Principle & System Control

Hospital elevators combine precision traction or hydraulic drive systems with variable-frequency control, floor-positioning feedback loops, and coordinated door operation to support the safe transit of patients, medical staff, beds, and heavy equipment.

Drive & Traction Architecture: Gearless traction configurations utilize Permanent Magnet Synchronous Motors (PMSM) paired with Variable Voltage Variable Frequency (VVVF) inverters. Closed-loop vector control regulates acceleration and deceleration, supporting smooth floor landing. Hydraulic configurations are available for low-rise applications where structural conditions require.


Control & Dispatch Logic: Microprocessor-based control systems manage car movement, door timing, and group supervisory dispatching. Available functions include emergency priority operation, group scheduling, and automatic fire emergency return. For facilities requiring priority transport, control logic—including Code Blue operation—is configured to match hospital workflows.


Emergency Power & Rescue Operation: An integrated Automatic Rescue Device (ARD) provides emergency power functionality during primary grid interruptions, driving the car to the nearest landing and opening doors per programmed rescue logic. Interface provisions for backup generator systems require coordination during electrical design.


Acoustic Performance & Interior Finishes: Drive equipment, car frames, and door operators are engineered to limit operating noise and vibration, maintaining interior noise thresholds suited for healthcare zones. Standard interior finishes include hairline stainless steel, medical-grade anti-static PVC, and vulcanized rubber, with material compatibility reviewed against project-specified chemical disinfectants.

 

Product Application

 

General hospitals, specialty hospitals, nursing homes, rehabilitation centers, medical examination centers.

Hospital Elevator12-2

 

Manufacturing & Quality Control

Manufacturing processes follow structured fabrication, mechanical assembly, electrical integration, and functional inspection protocols to ensure dimensional compatibility and operational reliability.

Structural Component Fabrication

Car frames, slings, and guide rail brackets undergo controlled CNC cutting, sheet metal processing, and welding procedures. Dimensions and mounting interfaces are verified against engineering drawings prior to assembly.

Dimensional Inspection & Assembly Verification

Critical structural dimensions and interface points are checked using measuring tools and alignment fixtures. Inspection records are maintained for production tracking where required.

Electrical & Mechanical Testing

Drive units, control cabinets, and mechanical assemblies undergo functional verification, including electrical insulation resistance tests, door operation cycles, braking torque checks, and safety device responses.

 

Factory Acceptance & Documentation

Pre-shipment inspections cover specified mechanical and electrical functions in accordance with project agreements. Technical documentation packages, including wiring diagrams and test records, are supplied upon delivery.

 

Customization & Project Support

Healthcare real estate projects involve specific spatial, structural, and system integration requirements.

 
 

Hoistway & Structural Adaptation

Car dimensions and door arrangements are adapted to available hoistway spaces. For retrofit projects, existing shaft dimensions, pit depths, and overhead clearances are reviewed prior to final design. Structural load reactions (static and dynamic forces at overhead slabs and pits) are calculated per project parameters.

 
 
 

Engineering Submittal Packages

Comprehensive drawing packages can be provided for architectural and MEP coordination, including general arrangement layouts, hoistway dimensions, overhead/pit requirements, load reactions, and electrical schematics.

 
 
 

Traffic Analysis Support

For multi-elevator facilities, building occupancy, floor distribution, and peak traffic demands can be evaluated to determine optimal elevator quantities, rated speeds, and dispatching algorithms.

 

 

 

Frequently Asked Questions

 

Q: What is the basis for setting the speed of the hospital stretcher elevator, and can it meet the time constraints of emergency rescue operations?

A: The speed of the elevator is set based on numerous factors. Generally, the vehicle speed between floors in a hospital ward is maintained at 0.25 to 0.5 meters per second. This allows for the smooth transportation of non-urgent patients, preventing discomfort caused by excessive speed. On the lines connecting the emergency room, operating rooms, and intensive care units, we have equipped the elevators with high-speed medical stretchers operating at speeds of 1.0 to 1.75 meters per second, ensuring that patients can reach their destinations quickly within the critical rescue timeframe.

Q: How can patient safety during elevator usage be ensured, particularly when using stretchers?

A: Safety protection is integrated throughout the entire design. Firstly, the doors are equipped with high-precision optical curtain protection, which boasts extremely high sensing accuracy. Even if a very thin medical tube blocks the light, the door will immediately stop closing and reopen to prevent strangulation. Secondly, the braking system employs redundant design and multiple braking safeguards. If the primary brake fails, the backup brake will immediately take effect, ensuring that the vehicle can come to a smooth stop in any emergency situation, with the braking distance strictly controlled within a narrow range. Additionally, the elevator features various intelligent protection mechanisms for overloading, shutdown, and slipping, continuously monitoring its operational state and providing comprehensive protection for patient safety.

Q: Heavy-duty medical elevators require the transportation of specialized medical equipment that is exceptionally long and tall. What specific design features are incorporated into these elevators for this purpose?

A: For this type of requirement, some cargo elevator cabins can be customized with removable cabin top sections and cabin wall panels. When transporting extremely tall equipment (such as large angiography machines), the corresponding cabin top panels can be removed to increase vertical space. For transporting exceptionally long equipment (such as long rehabilitation training tracks), some cabin wall panels can be removed to expand the horizontal passage space. Additionally, the elevator control system is pre-set to a “large equipment mode.” In this mode, the operating speed is appropriately reduced, and the opening time of the doors is extended, ensuring that specialized equipment can safely and completely enter and exit the elevator.

Q: What emergency measures should be taken by the bed elevator in response to a sudden power outage within a hospital to ensure the safety of patients?

A: The hospital bed elevator is equipped with an emergency power supply system. In the event of a power outage, the emergency power will immediately come online to ensure the proper functioning of the lighting and ventilation systems within the elevator car, thereby preventing patients from being left in a dark and stuffy environment. Additionally, the elevator will automatically and slowly descend to the nearest floor, come to a smooth stop, and open the doors. Throughout this entire process, the system is meticulously controlled to ensure the safe evacuation of both patients and medical personnel.

Q: How is noise control implemented during the operation of hospital bed elevators, given that hospitals require a quiet environment?

A: We have invested considerable effort into the noise reduction design of our elevators. The vehicles are equipped with materials that provide excellent sound insulation, effectively blocking mechanical noise during operation. Additionally, the drive system employs advanced silent technology, optimizing the design of motors and transmission components to minimize noise levels to less than 50 decibels during elevator operation. This volume is akin to a whisper and essentially does not interfere with patients’ rest or the tranquil environment of the hospital.

Q: How is leveling accuracy maintained when transporting hospital beds?

A: Elevator leveling relies on closed-loop drive feedback and magnetic floor sensors. The control system adjusts car position during landing to maintain precise alignment, minimizing vertical steps during stretcher and medical cart transfer.

Q: What door safety devices are utilized in hospital elevators?

A: Automatic doors are equipped with full-height infrared light curtains spanning multiple independent beams across the entrance plane. Obstruction detection instantly triggers a non-contact reopening response.

Q: What structural data must engineers provide for shaft design?

A: Building design teams must evaluate hoistway clear dimensions, overhead clearance, pit depth, guide rail bracket placement, and maximum load reactions at support slabs and buffers based on engineering calculation sheets.

Q: Can the elevator control system integrate with building management systems (BMS)?

A: Yes. Control cabinets can include dry contacts and serial communication interfaces for fire alarm interlocks, emergency power status, and central BMS status monitoring.

Q: What documentation is provided for local building authority approvals?

A: Documentation packages typically include technical specifications, general arrangement drawings, electrical wiring diagrams, structural load tables, and product conformity reports aligned with regional codes like EN 81-20/50 or ASME A17.1.

Q: What electrical power supply is required in the hoistway?

A: Systems require a dedicated 3-phase industrial power supply (e.g., 380V/415V or 480V), separate car lighting feeds, and independent emergency backup connections. Detailed load schedules are provided during the submittal phase.

 

modular-1
Request a Technical Proposal & Quotation

To evaluate your hospital elevator project and prepare an accurate technical proposal, please submit the following project parameters:
Elevator Application: Hospital Bed Elevator / Hospital Passenger Elevator / Service Elevator
Rated Load Capacity: (e.g., 1600 kg / 3500 lbs)
Rated Speed: (e.g., 1.0 m/s / 200 fpm)
Number of Floors / Stops:
Total Travel Height:
Hoistway Internal Dimensions: (Clear width x clear depth)
Required Car Dimensions: (Width x depth)
Clear Door Opening: (Width x height)
Drive Preference: Gearless Traction / Hydraulic / To Be Recommended
Power Supply Specification: (Voltage / Phase / Frequency)
Emergency Power Requirements: ARD / Generator Connection / Other Requirements

As one of the most professional hospital elevator manufacturers and suppliers in China, we're featured by quality products and good service. Please rest assured to buy custom made hospital elevator at competitive price from our factory. Contact us for more details.

Elevator for Hospital, hospital elevator, Icu Bed Elevator
Send Inquiry
Send Inquiry