Your attention to the elevator maintenance procedure and supervisory responsibilities is excellent, as this is indeed a crucial aspect of ensuring elevator safety. Understanding these details not only enhances safety awareness but also helps you assess whether the property management and maintenance company are fulfilling their duties.
Detailed Passenger Elevator Maintenance Procedure and Content: According to the "Elevator Maintenance Rules" (TSG T5002-2017), passenger elevator maintenance is divided into four categories: bi-weekly, quarterly, semi-annual, and annual, with progressively increasing items covering the entire process from basic inspections to systemic testing.
Bi-weekly Maintenance (Every 15 days) This is the most basic and frequent maintenance, focusing on ensuring daily operational safety:
Check the machine room environment: cleanliness, lighting, and whether emergency operating devices are complete.
Brakes: check clearance, lubrication pins, and whether the movement is flexible.
Door system: check whether the car door and landing door open and close smoothly, and whether the safety touch panel or light curtain is effective.
Safety Circuit: Functional testing of electrical safety devices such as emergency stop switch, inspection switch, and pit emergency stop.
Car Leveling Accuracy:Ensuring the floor stopping error is within ±5mm.
Emergency Lighting and Alarm Devices: Testing the five-way intercom and alarm bell for proper function.
Guide Rails and Guide Shoes:Checking lubrication and for any abnormal wear.
The bi-weekly maintenance items comprise approximately 55 items, serving as a "routine check-up" to ensure the daily safe operation of the elevator.
Quarterly Maintenance (Every 3 Months) In addition to the bi-weekly maintenance, in-depth inspections of key components are added:
Control Cabinet:Checking for burnt contactors and relay contacts, and for loose wiring.
Wire Rope Tension: Measuring the tension of each rope to ensure it is balanced, with a deviation not exceeding 5%.
Speed Governor: Cleaning and checking the smoothness of the operating mechanism.
Buffer: Checking the hydraulic buffer oil level and resetting function.
Traction sheave: Inspect the rope groove for wear, broken strands, or deformation.
Quarterly maintenance items total 42 items to further identify potential hazards.